Overview

To enhance the Canon Digital Radiography system, DR Image Viewer software provides an economical image viewing platform to meet the needs of orthopedic physicians, surgery centers, and emergency departments. Optional modules are available for stitching multiple images together and surgical planning using orthopedic implant templates.

 

Features

Scalable Platform
DR Image Viewer software allows the configuration of a single workstation server/viewer or multiple viewers on a single server. Using multiple viewers allows physicians to collaborate with each other or show images to the patient on desktop, laptop, or tablet computers. The software also supports the use of single or dual display devices.

DR Image Viewer Scalable Platform

Extensive Image Manipulation Tools
Standard tools, such as life-size view, brightness and contrast adjustment, measurement, pan/zoom, and annotate, are readily available from desktop icons. You can apply edge enhancement in 12 levels.  Orthopedic measurements such as cobb angle and transischial line require no additional software and are easy to use.

 

Multi-Image Screen Formatting
Need to split the window for viewing different projections of the patient exam or comparison images? DR Image viewer software allows for several of the most popular viewing window formats.

DR Image Viewer Cobb Angle
Click here for a larger image

 

DR Image Viewer Multiple Image Screen Layout

Cobb Angle

 

Multiple Image Screen Layout

     

Output to CD/DVD Burner
Included with the DR Image Viewer software is a CD/DVD viewing program called DR Image Viewer Light.  This viewer can be added to a CD/DVD of patient images for convenient image review by the patient or requesting physician on any compatible computer.

 

Output to PACS and Windows® and DICOM Printers
Images can be transmitted to most PACS.  Any text and graphics added during viewing are also transmitted.  Images can be printed using a Windows® printer or printed by a DICOM compatible printer in a variety of formats.

DR Image Viewer Light
Click here for a larger image

 

DR Image Viewer iPF510 Large Format Printer

DR Image Viewer Light

 

imagePROGRAF iPF510 Large Format Printer

     

Optional Modules for DR Image Viewer

   

Stitching Software
Canon offers an optional stitching module for DR Image Viewer software that allows stitching of multiple images, use of measurement tools, stitched image printing, and transmission of DICOM 3.0 compliant stitched images to PACS.

 

Implant Matching (templating) Software
An optional module for surgical planning of implanted orthopedic devices is available for DR Image Viewer software. An exceptional value, this low-cost tool is easy to use and includes bitmap-to-DICOM image conversion for templates prepared on a desktop scanner at a minimum of 150 dpi.

DR Image Viewer Stitching Image
Click here for a larger image

 

DR Image Viewer Implant Matching

Stitching Image

 

Implant Matching

 

For additional information, download the DR Image Viewer brochure.

Back to Top

System Requirements
DR Image Viewer is a software only product.  When purchasing a computer for your workstation(s), please note the system requirements as shown below.

 

Server / Viewer System Configuration

Operating System

Windows® Vista Business Edition
Windows® XP Professional SP2***
Windows® Server 2003 R2*

CPU

Pentium® 4, 1.8 GHz or higher

RAM

1 GB or higher (2 GB with Windows® Vista )

System Hard Disk

80 GB (RAID recommended)

Graphics Card

Windows® XP –
For common LCD monitor: Any 1600 x 1200 True Color, 32 bit, DirectX 9 Compatible, 128 MB graphic memory or more
For high resolution medical monitor: Differs by monitor specifications

Windows® Vista –
For common LCD monitor: Any 1600 x 1200 true color, 32 bit, DirectX 9 compatible, 128 MB graphic memory or more.  For high resolution medical monitor: No support at present.

Optical Disk Drive

CD-ROM
DVD-ROM with Windows® Vista

Peripherals

UPS
Desktop Scanner with a minimum of 150 dpi output (Required for Implant Matching option only)

 

 

----- OR -----

 

Server Configuration (Server & Viewer on separate computers)

Operating System

Windows® Vista Business Edition
Windows® XP Professional SP2***
Windows® Server 2003 R2

CPU

Pentium 4, 1.8 GHz or higher

RAM

1 GB or higher (2 GB with Windows® Vista )

System Hard Disk

80 GB or larger (RAID recommended)

Graphics Card

For common LCD monitor: Any 1024 x 768, True Color, 32 bit,
DirectX 9 Compatible, 32 MB graphic memory or more

Optical Disk Drive

CD-ROM
DVD-ROM with Windows® Vista

Peripherals

DVD RAM drive (optional) – required to utilize automatic image backup
UPS
Desktop Scanner with a minimum of 150 dpi output (Required for Implant Matching option only)

 

Viewer(s)** Configuration

Operating System

Windows® Vista Business Edition
Windows® Tablet PC Edition 2005
Windows® XP Professional SP2***

CPU

Pentium 4, 1.8 GHz or higher

RAM

1 GB or higher (2 GB with Windows Vista)

System Hard Disk

40 GB (7,200 RPM ATA100 or higher)

Graphics Card

Windows® XP –
For common LCD monitor: Any 1600 x 1200 True Color, 32 bit,
DirectX 9 Compatible, 128 MB graphic memory or more
For high resolution medical monitor: Differs by monitor specifications

Windows® Vista –
For common LCD monitor: Any 1600 x 1200 true color, 32 bit,
DirectX 9 compatible, 128 MB graphic memory or more
For high resolution medical monitor: No support at present

Optical Disk Drive

CR-ROM
DVD-ROM with Windows® Vista

Peripherals

UPS
Desktop Scanner with a minimum of 150 dpi output (Required for Implant Matching option only)

 

 

*Digital imaging and communications in medicine.  DICOM is a registered trademark of the National Electrical Manufacturers Association for its standards publications relating to digital communications of medical imaging.
**All additional viewers will have same system requirements.
***Needs to be 10 or less clients.  Otherwise, Windows® Server 2003 (R2) is required.

Back to Top

 

 
 
.
.
  Downloads | MSDS Search | Careers | Site Map | Contact Us | Product Advisories | Privacy Statement | Terms of Use Sign Up for RSS Feeds rss feed
  © 2009 Canon U.S.A., Inc. All Rights Reserved. Reproduction in whole or in part without permission is prohibited.